| DCS-O/15-27-38 |
Densons Cold Shrink Outdoor Terminations upto 38 kV
For XLPE Cable |
|
 |
"The term ' Cold Shrink'
is applied to materials, which are capable of shrinking without
raising the material above the ambient temperature of its immediate
surroundings. The Cold Shrink Accessories are supplied from the
factory in a pre-expanded condition and placed on a removable core.
Removing the core when properly positioned over the cables causes
shrinking."
Components :
• Cold Shrink Insulation Tube
• Cold shrink Breakout
• Cold Shrink Sealing Tube
• Roll Spring
• Sealing Mastic
• Void Filler
• Copper Mesh
• Phase Color Marking Tape
• Semi-Conductive Tape
• Silicon Grease
• Copper Binding Wire
• Cleaning Tissue
• Abrasive Strap
• Plastic Glove
* Specify for lug and other components |
| |
 |
| Features |
 |
 |
- Does not require heating by flaming or any special tools.
Just pull out the plastic expansion core from the silicon
rubber center and the stress cone will tightly shrink into
position.
- Reliable, superior insulation with high-recovery elasticity;
Denson Cold Shrink employs a special silicon rubber formulation
which keeps its radial pressure. This permanently ensures
the highest integrity of environmental & electrical
protection.
- Superior hermetic sealing; for cable splicing, Denson
has adopted a triple hermetic
sealing technology.
- Easy/convenient installation: the carefully engineered
dimensions of the pre-stressed cone provides for larger
tolerances and eases installation.
- Wide Usage: Denson’s expansive customer base spans
areas that pose great difficulties to electrical equipment
usage. Our Cold Shrink product line has a long and proven
track record showing superior performance in high pollution,
salt laden, thermally divergent locations. The Cold Shrink
accessories can be widely applied in various regions. It
is especially well suited for high altitudes, cold weather,
high-humidity, salt-fog & high-pollution regions.
|
| |
 |
| Specifications |
  |
 |
| TEST ITEMS OF COLD SHRINK OUTDOOR TERMINATIONS |
| TESTS |
15
kV |
| 60
Hz voltage test |
50kV,
1min, no flashover, no strike |
| Partial
discharge test |
13kV<1pc |
| Cyclic
load test, |
30
cycles under 90-95° C, 17kV |
| Impulses voltage
test |
110kV no flashover,
no strike |
| 6 Hrs, 60 Hz
voltage with standing test |
35kV, no flashover,
no strike |
| Salt fog test |
No any flashover, tracking,
erosion or mechanical damage occur at 1000h, 11kV |
|
| |
| 27 kV |
38 kV |
| 65kV, 1min,
no flashover, no strike |
90kV, 1min,
no flashover, no strike |
| 21.5kV<1pc |
30kV<2pc |
| 30 cycles under
90-95° C, 29kV |
30 cycles under
90-95° C, 40kV |
| 150kV no flashover,
no strike |
200kV no flashover,
no strike |
| 55kV, 15 min,
no flashover, no strike |
75kV, 15 min,
no flashover, no strike |
| No any flashover, tracking,
erosion or mechanical damage occur at 1000h, 16kV |
No any flashover,
tracking, erosion or mechanical damage occur at 1000h,
26kV |
|
|
|
| |
 |
| Ordering Information |
 |
| 15 kV 1 CORE OUTDOOR TERMINATIONS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 52-1/0
(25-50) |
DCSO
15-1 X 1 |
Enquiry |
| 2/0-4/0
(70-120) |
DCSO
15-1 X 2 |
Enquiry |
| 300-500
(150-240) |
DCSO
15-1 X 3 |
Enquiry |
| 600-800
(300-400) |
DCSO
15-1 X 4 |
Enquiry |
|
| |
| 15 kV 3 CORE OUTDOOR TERMINATIONS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
|
52-1/0 (25-50) |
DCSO
15-3 X 1 |
Enquiry |
|
2/0-4/0 (70-120) |
DCSO
15-3 X 2 |
Enquiry |
|
300-500 (150-240) |
DCSO
15-3 X 3 |
Enquiry |
|
600-800 (300-400) |
DCSO
15-3 X 4 |
Enquiry |
|
| |
| 27 kV 1 CORE OUTDOOR TERMINATIONS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 1/0-185
(50-95) |
DCSO
27-1 X 1 |
Enquiry |
| 4/0-400
(120-185) |
DCSO
27-1 X 2 |
Enquiry |
| 500-800
(240-400) |
DCSO
27-1 X 3 |
Enquiry |
|
| |
| 27 kV 3 CORE OUTDOOR TERMINATIONS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 1/0-185
(50-95) |
DCSO
27-3 X 1 |
Enquiry |
| 4/0-400
(120-185) |
DCSO
27-3 X 2 |
Enquiry |
| 500-800
(240-400) |
DCSO
27-3 X 3 |
Enquiry |
|
| |
| 38 KV 1 CORE OUTDOOR TERMINATIONS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 1/0-185
(50-95) |
DCSO
38-1 X 1 |
Enquiry |
| 4/0-400
(120-185) |
DCSO
38-1 X 2 |
Enquiry |
| 500-800
(240-400) |
DCSO
38-1 X 3 |
Enquiry |
|
| |
| 38 KV 3 CORE OUTDOOR TERMINATIONS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
|
1/0-185 (50-95) |
DCSO
38-3 X 1 |
Enquiry |
| 4/0-400
(120-185) |
DCSO
38-3 X 2 |
Enquiry |
| 500-800
(240-400) |
DCSO
38-3 X 3 |
Enquiry |
|
| |
|