Features
- Does not require heating by flaming or any special tools. Just pull out the plastic expansion core from the silicon rubber center and the stress cone will tightly shrink into position.
- Reliable, superior insulation with high-recovery elasticity; Denson Cold Shrink employs a special silicon rubber formulation which keeps its radial pressure. This permanently ensures the highest integrity of environmental & electrical protection.
- Superior hermetic sealing; for cable splicing, Denson has adopted a triple hermetic
sealing technology.
- Easy/convenient installation: the carefully engineered dimensions of the pre-stressed cone provides for larger tolerances and eases installation.
- Wide Usage: Denson’s expansive customer base spans areas that pose great difficulties to electrical equipment usage. Our Cold Shrink product line has a long and proven track record showing superior performance in high pollution, salt laden, thermally divergent locations. The Cold Shrink accessories can be widely applied in various regions. It is especially well suited for high altitudes, cold weather, high-humidity, salt-fog & high-pollution regions.
Specifications
TEST ITEMS OF COLD SHRINK OUTDOOR TERMINATIONS
| TESTING ITEMS U °/U |
TYPE 8.7/ 15 (17.5) KV |
| 50 Hz Voltage test |
39 kV, 5min, no flashover, no strite |
| Partial discharge test |
15 kV < 1pc |
| Cyclic load test, 3 cycles |
3 cycles under 90-95°C, 22kV |
| Impulses voltage test |
105kV no flashover, no strike |
| 15 min, 50 Hz voltage with standing test |
22kV, 15 min, no flashover, no strike |
| Salt fog test |
No any flashover, tracking, erosion or mechanical damage occur at 1000h, 11kV |
| 12/20 (24) kV |
18/30 (36) kV |
| 81 kV, 5min, no flashover, no strike |
117 kV, 5min, no flashover, no strike |
| 31 kV < 1pc |
45 kV < 2pc |
| 3 cycles under 90-95°C, 45kV |
3 cycles under 90-95°C, 65kV |
| 170kV no flashover, no strike |
200kV no flashover, no strike |
| 45kV, 15 min, no flashover, no strike |
65kV, 15 min, no flashover, no strike |
| No any flashover, tracking, erosion or mechanical damage occur at 1000h, 21kV |
No any flashover, tracking, erosion or mechanical damage occur at 1000h, 32.5kV |
Ordering Information
11 KV OUTDOOR TERMINATIONS
| CABLE CROSS SECTION (Sq. mm) |
FOR 11 kV 1 CORE OUTDOOR TERMINATION (Kit Code) |
|
| 25 - 50 |
DCSO 11-1X1 |
Enquiry |
| 70 - 120 |
DCSO 11-1X2 |
Enquiry |
| 150 - 240 |
DCSO 11-1X3 |
Enquiry |
| 300 - 400 |
DCSO 11-1X4 |
Enquiry |
| CABLE CROSS SECTION (Sq. mm) |
FOR 11 kV 3 CORE OUTDOOR TERMINATION (Kit Code) |
|
| 25 - 50 |
DCSO 11-3X1 |
Enquiry |
| 70 - 120 |
DCSO 11-3X2 |
Enquiry |
| 150 - 240 |
DCSO 11-3X3 |
Enquiry |
| 300 - 400 |
DCSO 11-3X4 |
Enquiry |
24 kV OUTDOOR TERMINATIONS
| CABLE CROSS SECTION (Sq. mm) |
FOR 12/20 (24) kV 1 CORE OUTDOOR TERMINATION (Kit Code) |
|
| 50 - 95 |
DCS0 24-1X1 |
Enquiry |
| 120 - 185 |
DCS0 24-1X2 |
Enquiry |
| 240 - 400 |
DCS0 24-1X3 |
Enquiry |
| CABLE CROSS SECTION (Sq. mm) |
FOR 12/20(24) kV 3 CORE OUTDOOR TERMINATION (Kit Code) |
|
| 50 - 95 |
DCSO 24-3X1 |
Enquiry |
| 120 - 185 |
DCSO 24-3X2 |
Enquiry |
| 240 - 400 |
DCSO 24-3X3 |
Enquiry |
36 KV OUTDOOR TERMINATIONS
| CABLE CROSS SECTION (Sq. mm) |
FOR 18/30(36) kV CABLE (1 CORE) OUTDOOR TERMINATION (Kit Code) |
|
| 50 - 95 |
DCSO 36-1X1 |
Enquiry |
| 120 - 185 |
DCSO 36-1X2 |
Enquiry |
| 240 - 400 |
DCSO 36-1X3 |
Enquiry |
| CABLE CROSS SECTION (Sq. mm) |
FOR 18/30(36) kV CABLE (3 CORE) OUTDOOR TERMINATION (Kit Code) |
|
| 50 - 95 |
DCSO 36-3X1 |
Enquiry |
| 120 - 185 |
DCSO 36-3X2 |
Enquiry |
| 240 - 400 |
DCSO 36-3X3 |
Enquiry |
|