Features
- It does not require heating by flaming nor special tools. Pull out the plastic string from silicon rubber tube, the silicon rubber will tightly shrink on the need position.
- Reliable, superior insulation & high-recovery elasticity; we have adopted special silicon rubber, which will keep its radial pressure permanently ensuring environmental & electrical protection.
- Superior hermetic sealing; for cable splicing, we have adopted triple hermetic sealing technology & silicon rubber with hermetic & hydrophobic performance; there will be no serious fault due to environmental cause.
- Easy/convenient installation : by enlarging the dimensions of stress-cone, large tolerance will be permitted & faults due to installation are reduced to a minimum.
- Wide Usage : possessing a series of superior performance such as anti-pollution, long usage, hydrophobic, cold-withstanding etc. The Cold Shrink accessories can be widely used in various regions, especially suitable for high level region, cold weather region, high-humidity region, salt-fog region & high-polluted region etc.
Specifications
TEST ITEMS OF COLD SHRINK INDOOR TERMINATIONS
| TESTING ITEMS U °/U |
TYPE 8.7/ 15 (17.5) KV |
| 50 Hz Voltage test |
39 kV, 5min, no flashover, no strite |
| Partial discharge test |
15 kV < 1pc |
| Cyclic load test, 3 cycles |
3 cycles under 90-95°C, 22kV |
| Impulses voltage test |
95kV no flashover, no strike |
| 15 min, 50 Hz voltage with standing test |
22kV, 15 min, no flashover,no strike |
| Humidity test |
No any flashover, tracking erosion or mechanical damage occur at 1000h, 11kV |
| 14.5/25 KV |
20.2/35 KV |
| 65 kV, 5min, no flashover, no strite |
91 kV, 5min, no flashover, no strite |
| 25 kV < 1pc |
35 kV < 2pc |
| 3 cycles under 90-95°C, 36kV |
3 cycles under 90-95°C, 51.5 kV |
| 125kV no flashover, no strike |
194kV no flashover, no strike |
| 36kV, 15 min, no flashover,no strike |
51kV, 15 min, no flashover,no strike |
| No any flashover, tracking erosion or mechanical damage occur at 1000h, 16kV |
No any flashover, tracking erosion or mechanical damage occur at 1000h, 24kV |
Ordering Information
15 kV INDOOR TERMINATIONS
| CABLE CROSS SECTION (Sq. mm) |
FOR 8.5 (15)kV 1 CORE INDOOR TERMINATION (Kit Code) |
|
| 25 - 50 |
DCSI 15-1X1 |
Enquiry |
| 70 - 120 |
DCSI 15-1X2 |
Enquiry |
| 150 - 240 |
DCSI 15-1X3 |
Enquiry |
| 300 - 400 |
DCSI 14-1X4 |
Enquiry |
| CABLE CROSS SECTION (Sq. mm) |
FOR 8.5 (15)kV 3 CORE INDOOR TERMINATION (Kit Code) |
|
| 25 - 50 |
DCSI 15-3X1 |
Enquiry |
| 70 - 120 |
DCSI 15-3X2 |
Enquiry |
| 150 - 240 |
DCSI 15-3X3 |
Enquiry |
| 300 - 400 |
DCSI 15-3X4 |
Enquiry |
24 kV INDOOR TERMINATIONS
| CABLE CROSS SECTION (Sq. mm) |
FOR 14.5 (25) kV 1 CORE INDOOR TERMINATION (Kit Code) |
|
| 50 - 95 |
DCSI 25-1X1 |
Enquiry |
| 120 - 185 |
DCSI 25-1X2 |
Enquiry |
| 240 - 400 |
DCSI 25-1X3 |
Enquiry |
| CABLE CROSS SECTION (Sq. mm) |
FOR 14.5 (25) kV 3 CORE INDOOR TERMINATION (Kit Code) |
|
| 50 - 95 |
DCSI 25-3X1 |
Enquiry |
| 120 - 185 |
DCSI 25-3X2 |
Enquiry |
| 240 - 400 |
DCSI 25-3X3 |
Enquiry |
35 KV INDOOR TERMINATIONS
| CABLE CROSS SECTION (Sq. mm) |
FOR 20.2 (35) kV 1 CORE INDOOR TERMINATION (Kit Code) |
|
| 50 - 95 |
DCSI 35-1X1 |
Enquiry |
| 120 - 185 |
DCSI 35-1X2 |
Enquiry |
| 240 - 400 |
DCSI 35-1X3 |
Enquiry |
| CABLE CROSS SECTION (Sq. mm) |
FOR 20.2 (35) kV 3 CORE INDOOR TERMINATION (Kit Code) |
|
| 25 - 70 |
DCSI 35-3X1 |
Enquiry |
| 95 - 185 |
DCSI 35-3X2 |
Enquiry |
| 240 - 400 |
DCSI 35-3X3 |
Enquiry |
|