| DCS-J/12-24-36 |
Densons Cold Shrink Straight
Through Joints upto 36 kV (For XLPE Cable) |
|
| |
"The term 'Cold Shrink' is applied to materials, which are
capable of shrinking without raising the material above the ambient
temperature of its immediate surroundings. The Cold Shrink Accessories
are supplied from the factory in a pre-expanded condition and placed
on a removable core. Removing the core when properly positioned
over the cables causes shrinking." |
| |
 |
Components :
• Semi-Conductive Tape
• Sealing Mastic
• Earthing braid
• Silicon grease
• Roll spring
• Phase Color Marking Tape
• Copper binding wire
• Cleaning tissue
• Abrasive strap
• Armour case
• Plastic glove
*Specify for lug and other components |
|
| |
| In conformance
with C 81, VDE 0278/ TAIL I, BS 6346 / 5467, IS 7098 (Part I), IS
1554, IS 694. |
 |
| Features |
 |
 |
- Simple structure, light in weight, single body joint reduction
jointer’s expertise, easy to install.
- Anti- Tracking / high electrical strength, unlimited shelf
life.
- Resistance to weather, UV light and salt pollution, no
explosion and fire hazard.
- The products are carefully selected compositions of raw
materials to meet the most stringent demands and compliance
to various international specifications and standards.
- Pre-engineered/inbuilt stress cone offering high stress
control properties.
|
 |
| Specifications |
 |
| TEST ITEMS OF COLD SHRINK STRAIGHT THROUGH JOINTS |
| TESTING
ITEMS U °/U |
TYPE
8.7/ 15 KV |
| 50
Hz Voltage test |
39
kV, 5min, no flashover, no strite |
| Partial
discharge test |
15
kV < 1pc |
| Cyclic
load test, 3 cycles |
3
cycles under 90-95°C, 22kV |
| Impulses voltage
test |
95kV no flashover,
no strike |
| 15 min, 50 Hz
voltage with standing test |
22kV, 15 min,
no flashover,no strike |
| Humidity test |
No any flashover,
tracking erosion or mechanical damage occur
at 1000h, 11kV |
|
| |
| 14.5/25 KV |
20.2/35 KV |
| 65 kV, 5min,
no flashover, no strite |
91 kV, 5min,
no flashover, no strite |
| 25 kV < 1pc |
35 kV < 2pc |
| 3 cycles under
90-95°C, 36kV |
3 cycles under
90-95°C, 51.5 kV |
| 125kV no flashover,
no strike |
194kV no flashover,
no strike |
| 36kV, 15 min,
no flashover,no strike |
51kV, 15 min,
no flashover,no strike |
| No any flashover,
tracking erosion or mechanical damage occur
at 1000h, 16kV |
No any flashover,
tracking erosion or mechanical damage occur
at 1000h, 24kV |
|
|
|
| |
 |
| Ordering Information |
 |
| 15 COLD SHRINK STRAIGHT THROUGH JOINTS |
| CABLE
CROSS SECTION (Sq. mm) |
FOR
8.7 (15) kV 1 CORE STRAIGHT
THROUGH JOINT (Kit Code) |
| 25
- 50 |
DCSJ
15-1X1 |
Enquiry |
| 70
- 120 |
DCSJ
15-1X2 |
Enquiry |
| 150
- 240 |
DCSJ
15-1X3 |
Enquiry |
| 300
- 400 |
DCSJ
15-1X4 |
Enquiry |
|
| |
| CABLE
CROSS SECTION (Sq. mm) |
FOR
8.7 (15) kV 3 CORE STRAIGHT
THROUGH JOINT (Kit Code) |
|
25 - 50 |
DCSJ
15-3X1 |
Enquiry |
|
70 - 120 |
DCSJ
15-3X2 |
Enquiry |
|
150 - 240 |
DCSJ
15-3X3 |
Enquiry |
|
300 - 400 |
DCSJ
15-3X4 |
Enquiry |
|
| |
| 24 kV COLD SHRINK STRAIGHT THROUGH JOINTS |
| CABLE
CROSS SECTION (Sq. mm) |
FOR
14.5 (25) kV 1 CORE STRAIGHT
THROUGH JOINT (Kit Code) |
| 50
- 95 |
DCSJ
25-1X1 |
Enquiry |
| 120
- 185 |
DCSJ
25-1X2 |
Enquiry |
| 240
- 400 |
DCSJ
25-1X3 |
Enquiry |
|
| |
| CABLE
CROSS SECTION (Sq. mm) |
FOR
14.5 (25) kV 3 CORE STRAIGHT
THROUGH JOINT (Kit Code) |
| 50
- 95 |
DCSJ
25-3X1 |
Enquiry |
| 120
- 185 |
DCSJ
25-3X2 |
Enquiry |
| 240
- 400 |
DCSJ
25-3X3 |
Enquiry |
|
| |
| 36 KV COLD SHRINK STRAIGHT THROUGH JOINTS |
| CABLE
CROSS SECTION (Sq. mm) |
FOR
20.2 (35) kV 1 CORE STRAIGHT
THROUGH JOINT (Kit Code) |
| 50
- 95 |
DCSJ
35-1X1 |
Enquiry |
| 120
- 185 |
DCSJ
35-1X2 |
Enquiry |
| 240
- 400 |
DCSJ
35-1X3 |
Enquiry |
|
| |
| CABLE
CROSS SECTION (Sq. mm) |
FOR
20.2 (35) kV 3 CORE STRAIGHT
THROUGH JOINT (Kit Code) |
| 50
- 95 |
DCSJ
35-3X1 |
Enquiry |
| 120
- 185 |
DCSJ
35-3X2 |
Enquiry |
| 240
- 400 |
DCSJ
35-3X3 |
Enquiry |
|
| |
|